首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Biomechanical properties of bovine tendon xenografts treated with a modern processing method
Institution:1. Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK;2. Musculoskeletal Surgery Group, Imperial College London School of Medicine, Charing Cross Hospital, London W6 8RF, UK;2. Graduate Medical Education, Saint Joseph Health System, Mishawaka, IN, United States;3. College of Pharmacy, University of Texas at Austin, Austin, TX, United States
Abstract:Xenograft tendons have been used in few human studies, with variable results. With the advent of novel tissue processing techniques, which may mitigate against an immune-mediated rejection response without adversely affecting mechanical properties, there may now be a clinical role for xenograft tendons, particularly in knee ligament reconstruction. We hypothesize that ‘BioCleanse®’ processed bovine extensor digitorum medialis (EDM) tendons exhibit favorable time-zero pre-implantation biomechanical characteristics when compared to both unprocessed bovine EDM tendons and BioCleanse® processed human cadaveric allograft tibialis anterior tendons.In this in vitro case controlled laboratory study, three groups of tendons underwent a 5-stage static loading test protocol: 15 BioCleanse® bovine (BCB), 15 fresh frozen unprocessed bovine (FFB), and 12 BioCleanse® human allograft (BCA) tendons. Cross-sectional area of the grafts was measured using an alginate molding technique, and tendons were mounted within an Instron® 5565 Materials Testing System using cryogenic clamps.BCB tendons displayed a higher ultimate tensile stress (p<0.05), with equivalent ultimate failure load, creep, and modulus of elasticity when compared to the FFB tendons (p>0.05). BCB tendons had an equivalent cross-sectional area to the BCA tendons (p>0.05) whilst exhibiting a greater failure load, ultimate tensile stress, less creep and a higher modulus of elasticity (p<0.05).The BioCleanse® process did not adversely affect the time-zero biomechanical properties of bovine xenograft EDM tendons. BioCleanse® processed bovine xenograft EDM tendons exhibited superior biomechanical characteristics when compared with BioCleanse® processed allograft tibialis anterior tendons. These findings support further investigation of xenograft tendons in orthopedic soft tissue reconstructive surgery.
Keywords:Knee ligaments  Xenograft  Sterilization  Biomechanics of tendon
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号