Hemodynamic characteristics of flow around a deformable stenosis
Institution:1. Department of Mechanical Engineering, University of Kentucky, Lexington, KY, United States;2. Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, United States;3. Gorman Cardiovascular Research Group and Department of Surgery, University of Pennsylvania, Philadelphia, PA, United States;4. Departments of Chemistry and Physics, University of Pennsylvania, Philadelphia, PA, United States;5. Department of Surgery, University of Kentucky, Lexington, KY, United States;1. Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA;2. Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA;3. Department of Radiology, Boston University School of Medicine, Boston, MA 02118, USA;1. Univ Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, F69622 Lyon, France;2. Univ Lyon, Université Claude Bernard Lyon 1, INSERM, Lyos UMR1033, F69622 Lyon, France;3. Service de Radiologie, Centre Hospitalier Lyon Sud, Pierre-Bénite, France;4. Service de chirurgie orthopédique et traumatologique – Hôpital d''instruction des armées Desgenettes, 69003 Lyon, France
Abstract:Clinical studies reported that some vulnerable stenoses deformed their shape in a blood vessel based on flow condition. However, the effects of shape variation on flow characteristics remain unclear. The flow characteristics are known to affect vulnerable stenosis rupture and fractional flow reserve (FFR) value which has been widely used as a diagnostic tool for stenosis. Vulnerable stenosis rupture occurs when the structural stress exerted on a fibrous cap exceeds its tolerable threshold. The stress magnitude is determined from the spatial distribution of static pressure around the stenosis. In the present study, the static pressure distribution and the FFR value in deformable stenosis were investigated with related other flow characteristics. Two phantom models were fabricated to mimic deformable and nondeformable stenoses using polydimethylsiloxane. The flow characteristics were observed under a steady-flow condition at three Reynolds numbers (Re = 500, 1000, 1500) using a particle image velocimetry. The pressure drop across the stenosis models were measured using a pressure sensor to determine effects of shape deformation on FFR value. Shape variations and jet deflections were clearly observed in the deformable stenosis model, and the effective severity of the stenosis increased up to 17.2%. The shape variations of deformable stenosis model increased the static pressure difference at the upstream and downstream sides of the stenosis. The pressure drop across the deformable stenosis model was significantly higher than that of the nondeformable stenosis model. The present results substantiate that stenosis deformability should be carefully considered to diagnose the rupture of vulnerable stenosis.
Keywords:Deformable stenosis  FFR  Flow characteristics  Hemodynamics  Rupture
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号