摘    要:目的:探讨微创内固定系统治疗对股骨远端骨折患者炎症应激反应和关节功能的影响。方法:收集2011年5月-2014年5月期间于我院接受治疗的股骨远端骨折患者100例,根据手术方式不同,将患者分为观察组和对照组,每组各50例。观察组患者给予微创内固定系统治疗,而对照组患者给予股骨髁钢板内固定治疗。比较两组患者术后炎症应激反应和关节功能状况。结果:观察组患者手术时间、手术中出血量、影像学检查患者愈合时间、完全负重下地活动时间均优于对照组,两组比较差异具有统计学意义(P0.05);术后6个月及12个月,观察组患者HSS评分与Harris评分均明显高于对照组,两组比较差异具有统计学意义(P0.05);手术后观察组患者的IL-1、ACTH、E、NE水平均明显优于对照组,比较差异具有统计学意义(P0.05)。结论:微创内固定系统治疗可有效减小手术创伤以及软组织的损伤,有效缓解患者炎症应激反应,进一步促进手术后骨折的愈合,改善患者关节功能,值得临床推广。

关 键 词:微创内固定系统  股骨远端骨折  关节功能

Minimally Invasive Internal Fixation on Inflammatory Stress Reaction andJoint Function of Patients with Distal Femur Fracture
Abstract:Objective:To investigate the effects of minimally invasive internal fixation system on inflammatory stress reaction andjoint function of patients with distal femur fracture.Methods:100 cases of patients undergoing the treatment of distal femoral fractures inMay 2011 to 2014 in our hospital were selected and according to the different methods, the patients were divided into two groups with 50cases in each group. The patients in the observation group were treated with minimally invasive internal fixation system, while thepatients in the control group were treated with femoral condyle plate fixation. Then the inflammatory reaction and joint function aftertreatment of the two groups were compared.Results:The operation time, amount of bleeding in operation, imaging examination inpatients with healing time, activity time with complete loads in the observation group were superior than the control group, withsignificant differences between the two groups (P<0.05); after the operation for 6 months and 12 months, the HSS and Harris scores in theobservation group were significantly higher than those of the control group, with significant differences between the two groups (P<0.05);after the operation, the IL-1, ACTHE and NE levels in the observation group were significantly better than those of the control group,with statistically significant differences (P<0.05).Conclusion:Minimally invasive internal fixation system can effectively reduce theoperation wound and soft tissue injury, which is worthy of clinical promotion.
Keywords:Minimally invasive internal fixation system   Distal femoral fractures   Joint function
本文献已被 CNKI 等数据库收录!
点击此处可从《现代生物医学进展》浏览原始摘要信息
点击此处可从《现代生物医学进展》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号