Determination of picogram levels of heptylphysostigmine in human plasma using high-performance liquid chromatography with fluorescence detection
Authors:M. L. Herold   M. L. Constanzer  B. K. Matuszewski
Abstract:A sensitive (50 pg/ml) method for the determination of heptylphysostigmine in human plasma is described. The procedure is based on liquid—liquid extraction of the drug from buffered plasma, and analysis of the concentrated organic extract using high-performance liquid chromatography on a silica column, under normal-phase chromatographic conditions, with fluorescence detection. Physostigmine was used as an internal standard. The assay has been fully validated in the concentration range 50–2000 pg/ml and utilized for the analysis of clinical samples from subjects dosed with heptylphysostigmine.