Micro determination of gentamicin in serum by high-performance liquid chromatography with ultraviolet detection |
| |
Authors: | Dirk M. Barends Johannes S.F. van der Sandt Abram Hulshoff |
| |
Affiliation: | Farmaceutisch Laboratorium, University of Utrecht, Catharijnesingel 60, 3511 GH Utrecht The Netherlands |
| |
Abstract: | A procedure for the high-performance liquid chromatographic determination of gentamicin in serum is described using pre-column derivatisation and UV detection. The serum proteins are precipitated with acetonitrile and the gentamicin components in the supernatant are derivatized with 1-fluoro-2,4-dinitrobenzene. The reaction products are chromatographed on a microparticulate C18 reversed-phase column and detected at 365 nm. Sample volumes of 50 μl are sufficient for the determination of gentamicin concentrations in, and well below, the therapeutic range. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|