Simultaneous measurement of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine by HPLC-MS/MS |
| |
Authors: | Podmore I D Cooper D Evans M D Wood M Lunec J |
| |
Affiliation: | Oxidative Stress Group, Division of Chemical Pathology, Leicester, LE2 7LX, United Kingdom. idp@le.ac.uk |
| |
Abstract: | An assay with high selectivity and sensitivity has been developed which, for the first time, allows quantitative, simultaneous measurement in DNA of both 8-oxo-2'-deoxyguanosine (8-oxodG) and 8-oxo-2'-deoxyadenosine (8-oxodA)-important biomarkers of oxidative DNA damage in vivo. Using reversed-phase HPLC coupled to electrospray tandem mass spectrometry (HPLC-MS/MS) in multiple reaction monitoring (MRM) mode it was possible to detect background levels of these lesions in commercially available calf thymus DNA (85 +/- 3 and 7.1 +/- 0.2 per 10(6) DNA bases for 8-oxodG and 8-oxodA respectively; n = 3). Levels of 8-oxodG determined by HPLC coupled to an electrochemical detection system (HPLC-EC) were found to be similar (75 +/- 6 per 10(6) DNA bases; n = 3) to those obtained using tandem mass spectrometry. |
| |