Finger Prick Dried Blood Spots for HIV Viral Load Measurement in Field Conditions in Zimbabwe
Authors:Sue Napierala Mavedzenge  Calum Davey  Tarisai Chirenje  Phyllis Mushati  Sibongile Mtetwa  Jeffrey Dirawo  Boniface Mudenge  Andrew Phillips  Frances M. Cowan
Affiliation:1Women’s Global Health Imperative, RTI International, San Francisco, California, United States of America;2London School of Hygiene and Tropical Medicine, London, United Kingdom;3Centre for Sexual Health and HIV/AIDS Research Zimbabwe, Harare, Zimbabwe;4Flowcytometry Laboratory, Harare, Zimbabwe;5University College London, London, United Kingdom;University of Liverpool, UNITED KINGDOM
Abstract:BackgroundIn the context of a community-randomized trial of antiretrovirals for HIV prevention and treatment among sex workers in Zimbabwe (the SAPPH-IRe trial), we will measure the proportion of women with HIV viral load (VL) above 1000 copies/mL (“VL>1000”) as our primary endpoint. We sought to characterize VL assay performance by comparing results from finger prick dried blood spots (DBS) collected in the field with plasma samples, to determine whether finger prick DBS is an acceptable sample for VL quantification in the setting.MethodsWe collected whole blood from a finger prick onto filter paper and plasma samples using venipuncture from women in two communities. VL quantification was run on samples in parallel using NucliSENS EasyQ HIV-1 v2.0. Our trial outcome is the proportion of women with VL>1000, consistent with WHO guidelines relating to regimen switching. We therefore focused on this cut-off level for assessing sensitivity and specificity. Results were log transformed and the mean difference and standard deviation calculated, and correlation between VL quantification across sample types was evaluated.ResultsA total of 149 HIV-positive women provided DBS and plasma samples; 56 (63%) reported being on antiretroviral therapy. VL ranged from undetectable-6.08 log10 using DBS and undetectable-6.40 log10 using plasma. The mean difference in VL (plasma-DBS) was 0.077 log10 (95%CI = 0.025–0.18 log10; standard deviation = 0.63 log10,). 78 (52%) DBS and 87 (58%) plasma samples had a VL>1000. Based on plasma ‘gold-standard’, DBS sensitivity for detection of VL>1000 was 87.4%, and specificity was 96.8%.ConclusionThere was generally good agreement between DBS and plasma VL for detection of VL>1000. Overall, finger prick DBS appeared to be an acceptable sample for classifying VL as above or below 1000 copies/mL using the NucliSENS assay.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号