An assessment of a 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Institution:1. Groupe Oncorad-Garonne, Service de Radiothérapie, Clinique Pasteur, L''Atrium, 1, rue de la Petite-vitesse, 31300 Toulouse, France;2. INSERM, Imagerie Cérébrale et Handicaps Neurologiques, UMR 825, F-31059 Toulouse, France;3. Groupe Oncorad-Garonne, Service de Radiothérapie, Clinique du Pont-de-Chaume, 330 avenue Marcel-Unal, 82000 Montauban, France;4. INSERM UMR 1037, Team 15: Multi-resolution dosimetry for radiotherapy optimisation, Centre de recherche en Cancérologie de Toulouse, F-31062 Toulouse, France;5. Université Toulouse III-Paul Sabatier, UMR1037 CRCT, F-31000 Toulouse, France
Abstract:PurposeTo provide a 3D dosimetric evaluation of a commercial portal dosimetry system using 2D/3D detectors under ideal conditions using VMAT.MethodsA 2D ion chamber array, radiochromic film and gel dosimeter were utilised to provide a dosimetric evaluation of transit phantom and pre-treatment ‘fluence’ EPID back-projected dose distributions for a standard VMAT plan. In-house 2D and 3D gamma methods compared pass statistics relative to each dosimeter and TPS dose distributions.ResultsFluence mode and transit EPID dose distributions back-projected onto phantom geometry produced 2D gamma pass rates in excess of 97% relative to other tested detectors and exported TPS dose planes when a 3%, 3 mm global gamma criterion was applied. Use of a gel dosimeter within a glass vial allowed comparison of measured 3D dose distributions versus EPID 3D dose and TPS calculated distributions. 3D gamma comparisons between modalities at 3%, 3 mm gave pass rates in excess of 92%. Use of fluence mode was indicative of transit results under ideal conditions with slightly reduced dose definition.Conclusions3D EPID back projected dose distributions were validated against detectors in both 2D and 3D. Cross validation of transit dose delivered to a patient is limited due to reasons of practicality and the tests presented are recommended as a guideline for 3D EPID dosimetry commissioning; allowing direct comparison between detector, TPS, fluence and transit modes. The results indicate achievable gamma scores for a complex VMAT plan in a homogenous phantom geometry and contributes to growing experience of 3D EPID dosimetry.
Keywords:Absolute dosimetric verification  Portal dosimetry  EPID  3D dose comparison  VMAT
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号