Conduction disturbances related to percutaneous balloon mitral valvuloplasty |
| |
Authors: | Antonelli Dante Turgeman Yoav Rosenfeld Tiberio |
| |
Institution: | Department of Cardiology, Ha'Emek Medical Center, 18101 Afula, Israel. |
| |
Abstract: | During the performance of 280 consecutive percutaneous balloon mitral valvuloplasty operations, two cases of conduction disturbances were reported (0.7%). These rare complications are transient and due to the mechanical pressure of the balloon on the conduction system. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|