Determination of diethylstilbestrol based on biotin–streptavidin‐amplified time‐resolved fluoro‐immunoassay
Authors:Lingyun Du  Shuang Cheng  Shuhao Wang
Institution:1. College of Chemistry and Chemical Engineering, Liaocheng University, , People's Republic of China;2. College of Agricultural Science, Liaocheng University, , People's Republic of China
Abstract:A rapid and sensitive time‐resolved fluoroimmunoassay (TR–FIA) based on the biotin–streptavidin amplification system was developed for the determination of diethylstilbestrol (DES). Europium‐labelled streptavidin derivatives combined with europium and anhydride of diethylene triamine penta‐acetic acid were used to label streptavidin; biotin was coupled with goat anti‐rabbit IgG to form a biotin–goat anti‐rabbit IgG bridge between streptavidin–europium and the anti‐DES antibody in the immunoassay. The DES assay was carried out by measuring the fluorescence of Eu3+–SA at 615 nm. The presented method produced a wide linear range, 0.001–1000.0 ng/mL, and a detection limit up to 0.81 pg/mL for DES. The method was applied to determine DES in serum samples, with recoveries of 97.4–107.8% and RSD 1.32–4.04%. The assay results by the present method showed that biotin–streptavidin amplified TR–FIA for DES detection; it may offer high sensitivity and promising alternative special methods in biological samples. Copyright © 2011 John Wiley & Sons, Ltd.
Keywords:time‐resolved fluoroimmunoassay  biotin–  streptavidin amplification system  diethylstilbestrol  europium