首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Quantification of the Thyroid Scan (TS) and correlation to Multiparametric Ultrasounds (MPUS): A textbook case of nuclear molecular imaging
Institution:1. Department of Radiology, Sanliurfa Children’s Hospital, Sanliurfa, Turkey;2. Department of Radiology, Umraniye Training and Research Hospital, Istanbul, Turkey;3. Department of Pathology, Marmara University Hospital, Istanbul, Turkey;4. Department of Radiology, Marmara University Hospital, Istanbul, Turkey
Abstract:For decades, thyroid scintigraphy (TS) has been considered an interesting tool, especially in the field of hyperthyroidism. In recent years, TS has rapidly gained importance since it provides unique molecular information that cannot be obtained by any other modality. In fact, despite a limited 6 mm spatial resolution, it can highlight molecular and histo-functional changes that characterize most thyroid function disorders. However, to become such a powerful molecular image, the TS must be quantified. How much iodine is taken-up characterizes the Uptake (Up), while where iodine distributes characterizes the Spatial Targeting (ST). Methodology, results and limits of the thyroid Uptake are presented, including suppressed tests. Methods to determine the anatomical thyroid volume are revisited with special focus on planar scintigraphy. Recent developments in quantification make the 123I-TS a new molecular imaging procedure. Since 123I targets the sodium iodide symporter (NIS) and tracks the whole organification process, we derived a fundamental linear relationship between the TSH and the precocious (120–240 min) Uptake (p123IUp). This relationship indicates whether the 123I input follows the physiological TSH stimulation or is predictive of a non TSH-suppressible function, whatever the imaging pattern. This allows identification of toxic or compensated (TSH > 0.1 mU/L) Thyroid Functional Autonomy (TFA), even at baseline. Spatial Targeting, measured with the aid of computational algorithms, provides a reproducible Spatial Targeting Index (STI). This allows estimating a functional thyroid volume, that is likely more informative than the anatomical one. Most aspects of TS quantification and the interest to compare the structure (mostly MultiParametric US) and the function (molecular 123I-TS) are presented.
Keywords:Thyroid Scan  Thyroid Uptake  Image Quantification  Suppressed Scan  Functional Volume  Molecular imaging  Thyroid Functional Autonomy  Scintigraphie Thyroïdienne  Fixation thyroïdienne  Quantification de l’image  Scintigraphie freinée  Volume fonctionnel  Imagerie moléculaire  Syndrome d’autonomisation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号