首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Evaluation of fused-core and monolithic versus porous silica-based C18 columns and porous graphitic carbon for ion-pairing liquid chromatography analysis of catecholamines and related compounds
Authors:Chirita Raluca-Ioana  Finaru Adriana-Luminita  Elfakir Claire
Institution:Institut de Chimie Organique et Analytique CNRS UMR 6005, University of Orléans, BP 6759, 45067 Orléans, France.
Abstract:This paper evaluates the performances of reversed-phase (RPLC) and ion-pairing chromatography (IPLC) coupled with UV detection for the analysis of a set of 12 catecholamines and related compounds. Different chromatographic columns (porous C18-silica, perfluorinated C18-silica, porous graphitic carbon, monolithic and fused-core silica-based C18 columns) were tested using semi-long perfluorinated carboxylic acids as volatile ion-pairing reagents. Much more promising results were obtained by IPLC than by RPLC and important improvements in analytes peak symmetry and separation resolution were observed when using the "fast chromatography" columns (monolithic and fused-core C18) under IPLC conditions. For UV detection, a satisfactory separation of the 12 selected analytes was achieved in less than 20 min by using a fused-core particles column (Halo C18) and a mobile phase composed of a 1.25 mM nonafluoropentanoic acid aqueous solution and methanol under gradient elution mode. The chromatographic method developed can be directly coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS) in positive ionization mode and 10 solutes among those selected can be observed. The presence of the acidic ion-pairing reagent in the mobile phase makes this system incompatible with negative ionization mode and thus unable to detect the two acidic compounds that only responded in negative mode. In terms of MS detection, Monolithic C18 column proved to be the best one to reach the lowest detection limits (LODs) (from 0.5 ngmL(-1) to 10 ngmL(-1) depending on the neurotransmitter). The applicability of the optimized LC-MS/MS method to a "real world" sample was finally evaluated. The presence of the matrix leads to signal suppression for several solutes and thus to higher LODs.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号