首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Precise Stent Placement Using the New Siemens Artis Zeego 3D Rotation Angiography in a Stenosis of a Shelhigh Pulmonary Conduit
Authors:Diegeler Anno  Fröhner Stefan  Dähnert Ingo
Institution:From the Departments of *Cardiac Surgery and ?Radiology, Herz-und Gef??klinik Bad Neustadt-Germany, Bad Neustadt, Germany; and ?Department of Pediatric Cardiology, Herzzentrum, Univers?t Leipzig-Germany, Leipzig, Germany.
Abstract:Stenting of the Shelhigh pulmonary conduit was performed 2 years after a Ross procedure because of a stenosis of the distal segment. We used the new Siemens Artis Zeego technology. A precise placement of the stent to release the stenosis within the distal segment simultaneously retaining a competent valve was possible by using the Dyna-computed tomography technology. The early onset of a stenosis of the Shelhigh xenograft in the pulmonary position is alarming, thus, its use can not be recommended for a replacement of the pulmonary valve.