首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of dimethylglycine in biological fluids
Authors:D H Porter  M Lin  C Wagner
Affiliation:1. Hospital Clínic, IDIBAPS, CIBERER, Barcelona, Spain;2. Clinica Universitária de Navarra, Facultad Medicina, Pamplona, Spain;3. Hospital Vall d''Hebron, UAB, Barcelona, Spain;4. Hospital Sant Joan de Deu, CIBERER, Barcelona, Spain;5. Wellcome Trust Centre for Mitochondrial Research, Institute of Neuroscience, Newcastle University, Newcastle upon Tyne, United Kingdom;6. CSIC, Barcelona, Spain
Abstract:The method of quantitating N,N-dimethylglycine involves cation-exchange high-performance liquid chromatography and detection of dimethylglycine with dimethylglycine dehydrogenase. Dimethylglycine was added to plasma and urine and samples were assayed for dimethylglycine. Plasma and urine to which no dimethylglycine was added were also assayed. Recoveries of added dimethylglycine were 99 to 104% with no endogenous dimethylglycine found in rat plasma or normal human urine. The human plasma used contained a small amount of endogenous dimethylglycine. The cation-exchange chromatography separates dimethylglycine from other compounds which can serve as substrates for dimethylglycine dehydrogenase. Repeatability of the assay is +/- 10%. Using this method we have identified dimethylglycine in the urine of a 1-month-old female human patient.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号