Correction of thermal gradient errors in stem thermocouple hygrometers
Authors:Michel B E
Institution:Department of Botany, University of Georgia, Athens, Georgia 30602.
Abstract:Stem thermocouple hygrometers were subjected to transient and stable thermal gradients while in contact with reference solutions of NaCl. Both dew point and psychrometric voltages were directly related to zero offset voltages, the latter reflecting the size of the thermal gradient. Although slopes were affected by absolute temperature, they were not affected by water potential. One hygrometer required a correction of 1.75 bars water potential per microvolt of zero offset, a value that was constant from 20 to 30 C.