首页 | 本学科首页   官方微博 | 高级检索  
   检索      


A numerical and experimental comparison of human head phantoms for compliance testing of mobile telephone equipment
Authors:Christ Andreas  Chavannes Nicolas  Nikoloski Neviana  Gerber Hans-Ulrich  Pokovi? Katja  Kuster Niels
Institution:Foundation for Research on Information Technologies in Society, H-8004 Zürich, Switzerland. christ@itis.ethz.ch
Abstract:A new human head phantom has been proposed by CENELEC/IEEE, based on a large scale anthropometric survey. This phantom is compared to a homogeneous Generic Head Phantom and three high resolution anatomical head models with respect to specific absorption rate (SAR) assessment. The head phantoms are exposed to the radiation of a generic mobile phone (GMP) with different antenna types and a commercial mobile phone. The phones are placed in the standardized testing positions and operate at 900 and 1800 MHz. The average peak SAR is evaluated using both experimental (DASY3 near field scanner) and numerical (FDTD simulations) techniques. The numerical and experimental results compare well and confirm that the applied SAR assessment methods constitute a conservative approach.
Keywords:dosimetry  FDTD methods  measurement techniques
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号