Microbiological Evaluation of Suture Items Before Radiation Sterilization
Authors:Bertil O. ?sterberg
Abstract:Microbiological contamination levels of suture samples taken at various stages of the manufacturing process in a new hygienically controlled plant were determined by employing a membrane filturation technique. Both raw material and materials handled manually in the production process were tested to assess the effect of manual handling on the product contamination level. Evaluation of the efficacy of contamination control, however, was directed primarily to the finished, packaged products, just prior to the processing with cobalt 60. The suture material for testing was divided into two groups, namely, wet and dry products, the wet being packaged in a special "tubing" fluid consisting mainly of isopropyl alcohol. Initial contamination results are reported as the average of values obtained on the test day and the preceding 9 consecutive production days. A total of 1,787 suture samples tested in the dry group showed daily averages varying between 2.1 and 14.8 contaminants per suture. The 2,980 wet-packaged suture samples tested gave daily averages varying from 0.7 to 4.2 contaminants per suture. The highest values obtained for an individual suture were 400 for the dry and 89 for the wet. Identification studies of the contaminants revealed that fungi predominated. Most of the bacterial contaminants proved to be spore-forming rods.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏