首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Transport-dependent alterations of membrane properties of mammalian colon measured using impedance analysis
Authors:N K Wills  C Clausen
Institution:(1) Department of Physiology, Yale University School of Medicine, 06437 New Haven, Connecticut;(2) Department of Physiology and Biophysics, Health Science Center, 11794-8861 Stony Brook, New York;(3) Present address: Department of Physiology and Biophysics, University of Texas Medical Branch, 77550-2781 Galveston, TX
Abstract:Summary Direct current (DC) measurement methods have been commonly used to characterize the conductance properties of the mammalian colon. However, these methods provide no information concerning the effects of tissue morphology on the electrophysiological properties of this epithelium. For example, distribution of membrane resistances along narrow fluid-filled spaces such as the lateral intercellular spaces (LIS) or colonic crypts can influence DC measurements of apical and basolateral membrane properties. We used impedance analysis to determine the extent of such distributed resistance effects and to assess the conductance and capacitance properties of the colon. Because capacitance is proportional to membrane area, this method provides new information concerning membrane areas and specific ionic conductances for these membranes.We measured transepithelial impedance under three conditions: (1) control conditions in which the epithelium was opencircuited and bathed on both sides with NaCl–HCO3 Ringer's solutions, (2) amiloride conditions which were similar to control except that 100 mgrm amiloride was present in the mucosal bathing solution, and (3) mucosal NaCl-free conditions in which mucosal Na and Cl were replaced by potassium and sulfate or gluconate (ldquoK+ Ringer'srdquo). Three morphologically-based equivalent circuit models were used to evaluate the data: (1) a lumped model (which ignores LIS resistance), (2) a LIS distributed model (distributed basolateral membrane impedance) and (3) a crypt-distributed model (distributed apical membrane impedance). To estimate membrane impedances, an independent measurement of paracellular conductance (G s ) was incorporated in the analysis. Although distributed models yielded improved fits of the data, the distributed and lumped models produced similar estimates of membrane parameters. The predicted effects of distributed resistances on DC microelectrode measurements were largest for the LIS-distributed model. LIS-distributed effects would cause a 12–15% underestimate of membrane resistance ratio (R a /R b ) for the control and amiloride conditions and a 34% underestimate for the ldquoK Ringer'srdquo condition. Distributed resistance effects arising from the crypts would produce a 1–2% overestimate ofR a /R b .Apical and basolateral membrane impedances differed in the three different experimental conditions. For control conditions, apical membrane capacitance averaged 21 mgrF/cm2 and the mean apical membrane specific conductance (G a-norm) was 0.17 mS/mgrF. The average basolateral membrane capacitance was 11 mgrF/cm2 with a mean specific conductance (G b-norm) of 1.27 mS/mgrF.G a-norm was decreased by amiloride or ldquoK+ ringer'srdquo to 0.07 mS/gmF and 0.06 mS/mgrF, respectively. Basolateral conductance was also reduced by amiloride, whereas capacitance was unchanged (G b-norm=0.97 mS/mgrF). For the ldquoK+ Ringer's condition, both basolateral conductance and capacitance were greatly increased such thatG b-norm was not significantly different from the control condition.
Keywords:impedance analysis  epithelium  colon  amiloride  equivalent circuit analysis
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号