Soluble CD40 ligand as a biomarker for storage-related preanalytic variations of human serum |
| |
Authors: | Lengellé Juliette Panopoulos Evangelos Betsou Fotini |
| |
Affiliation: | Biobanque de Picardie, BP7, CHU d'Amiens, Avenue René La?nnec, 80480 Salouel, France. |
| |
Abstract: | There are currently no appropriate and sensitive biomarkers available to assess preanalytic variations in human biological fluids stored in biobanks. We identified soluble CD40 ligand (sCD40L) as the first ubiquitous biomarker to show an on-off response in serum exposed to moderate or elevated room temperature conditions. We used immunoenzyme assays to monitor the sCD40L response after 12 h storage at 37 degrees C or 48 h at 20 degrees C. Our findings show that prolonged storage of serum samples at elevated room temperature can be determined by the absence of detectable sCD40L. |
| |