首页 | 本学科首页   官方微博 | 高级检索  
     


Residential magnetic field measurements in France: comparison of indoor and outdoor measurements.
Authors:F Clinard  C Milan  M Harb  P M Carli  C Bonithon-Kopp  J P Moutet  J Faivre  P Hillon
Affiliation:Registre Bourguignon des Cancers Digestifs (INSERM CRI 9505), Faculté de Médecine, Dijon, France. francois.clinard@u-bourgogne.fr
Abstract:Residential magnetic field (MF) measurements were performed for the first time in a representative sample of French dwellings. Exposure levels were assessed by two methods: indoor and outdoor measurements. Linear and logistic regression models were used to determine factors associated with the time-weighted average (TWA) home MF. TWA magnetic field magnitudes were approximately log-normally distributed with geometric means under 0.010 microT for both indoor and outdoor measurements. Only 5% of the dwellings presented indoor MF levels greater than 0.120 microT (1.2 mG). Both indoor and outdoor MF variations were explained by three factors: wiring configuration, the dwelling's location (i.e., urban or rural), and housing characteristics (individual houses or apartment building). The reliability of outdoor spot measurements with 30-min bedroom recordings was assessed by an intraclass correlation coefficient. The measurements were accurate in rural areas and small towns. In urban centers, local MF variations spoil the outdoor measurement's reliability. If indoor measurements are taken as the reference method, the use of outdoor instead of indoor measurement leads to an important decrease in statistical power. Further assessment of MF near high power transmission lines is necessary to evaluate the usefulness of outdoor spot recordings near such lines. The urban MF environment also has to be explored to identify extraneous sources.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号