首页 | 本学科首页   官方微博 | 高级检索  
   检索      


The correction of reaction rates in continuous fluorometric assays of enzymes
Authors:Alves Antônio Carlos Vassalo  Rogana Edyr  Barbosa Célia de Fátima  Ferreira-Alves Dalton L
Institution:Department of Physiology and Biophysics, Institute of Biological Sciences (UFMG), Avenida Pres. Ant?nio Carlos 6627, CEP 31270-901-Campus Pampulha, Belo Horizonte, MG Brazil.
Abstract:The kinetic data obtained from the action of a cathepsin D-like enzyme from Biomphalaria glabrata hepatopancreas (digestive gland) on MOCAc-Gly-Lys-Pro-Ile-Leu-Phe-Phe-Arg-Leu-Lys(DNp)-D-Arg-NH(2), was studied as a data prototype, generated by means of a fluorogenic substrate. An initial fluorescence, due to incomplete energy transfer, of about 8% of the values attained after complete substrate hydrolysis; a non-linear standard curve even at microM concentrations and an exponential decay of the steady state fluorescence of reaction product of the order of 10(-4) x s(-1) were the main analytical problems encountered. The standard curves for fluorescence of the substrate reaction product after 48 h of hydrolysis, and the reference compound MOCAc-Pro-Leu-Gly-NH(2), were fitted by polynomial approximation and the point derivates used as calibration factors. Time dependence of the calibration factor for the reaction product was -2.96 x 10(-4) a.u microM(-1) x s(-1) that is, in the same order of observed enzymic reaction rates. A mathematical treatment was devised for obtaining rates corrected for errors derived from the three analytical problems indicated. The method is of general application in continuous fluorometric assays, irrespective of the particular enzyme used, but of special value for substrates that present significant initial fluorescence. The reaction rates were 11% higher; as calculated by means of the calibration factor substrate]/(final-initial fluorescence intensities), which is the prevalent procedure in the literature; leading to underestimation of K(m) and overestimation of V(max).
Keywords:A  Acceptor chromophore  D  Donor chromophore  Dnp  N-2  4-dinitrophenyl  DMSO  Dimethylsulfoxide  f  Fluorophore  F  Fluorescence intensity  F(P)  Reaction product fluorescence  FR  Fluorescence resultant  F(S)  Substrate initial fluorescence  g([f])  Function of fluorophore concentration  g([p])  Function of product concentration  g([s])  Function of substrate concentration  MOCAc  (7-methoxycoumarin-4-yl)acetyl
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号