首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Effect of prefabricated thermoformable foot orthoses on plantar surface temperature after running: A gender comparison
Institution:1. A.V. Luikov Heat and Mass Transfer Institute, P. Brovka Str., 15, Minsk, 220072, Belarus;2. Don State Technical University, Shevchenko Str., 147, Shakhty, 346500, Russia;3. University of Rostock, Chair of Modelling and Simulation, Albert-Einstein-Straße 2, Rostock,18059 Germany;1. Discipline of Podiatry, School of Allied Health, Human Services and Sport, College of Science, Health and Engineering, La Trobe University, Melbourne, Victoria 3086, Australia;2. La Trobe Sport and Exercise Medicine Research Centre, School of Allied Health, Human Services and Sport, College of Science, Health and Engineering, La Trobe University, Melbourne, Victoria 3086, Australia
Abstract:There is a lack of evidence about the effect of different type of foot orthoses on plantar surface temperature. Moreover, that effect could be different depending on gender due to anatomical and physiological differences between men and women. The aim of the study was to analyze the effect of a prefabricated thermoformable foot orthosis on plantar surface temperature after running and taking gender differences into account. Thirty recreational runners (15 males, mean (standard deviation): 28 (7) years, 69.7 (6.5) kg, 1.74 (0.05) cm and 22.9 (1.7) kg/m2; and 15 females: 35 (7) years, 55.2 (6.9) kg, 1.63 (0.06) cm and 20.6 (1.9) kg/m2) carried out a maximum incremental test as pre-test, and two running tests on a treadmill at the laboratory wearing previously randomized different foot orthoses (thermoformable and prefabricated generic). The plantar surface temperature of the dominant foot sole in ten regions of interest was assessed before and immediately after 30-min running at 75% of VO2max. The use of thermoformable foot orthoses produced lower temperatures only in men after the run in medial heel (P = 0.033, ES = 0.7), which then disappeared in temperature variation (after – before) (P = 0.910). Regarding gender, women showed lower temperatures before the run in both orthosis conditions (P < 0.039, ES > 0.8), but no differences in temperatures after the run (P = 0.910) in comparison with men. Moreover, absolute temperatures after running were always greater than before the run (P < 0.001, ES > 5.0). In conclusion, the thermoformable foot orthoses do not modify plantar surface temperature after running in healthy runners of either gender, compared to prefabricated generic foot orthoses. Although women present lower baseline plantar temperatures than men, these differences disappear after exercise.
Keywords:Insoles  Foot sole  Running  Infrared thermography  Gender
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号