首页 | 本学科首页   官方微博 | 高级检索  
     


In-vivo mitral annuloplasty ring transducer: Implications for implantation and annular downsizing
Authors:Andrew W. Siefert  Steven A. Touchton Jr.  Jeremy R. McGarvey  Satoshi Takebayashi  Jean Pierre M. Rabbah  Jorge H. Jimenez  Neelakantan Saikrishnan  Robert C. Gorman  Joseph H. Gorman III  Ajit P. Yoganathan
Affiliation:1. The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 Ferst Drive, Atlanta, GA 30332, USA;2. Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, PA, USA
Abstract:Mitral annuloplasty has been a keystone to the success of mitral valve repair in functional mitral regurgitation. Understanding the complex interplay between annular-ring stresses and left ventricular function has significant implications for patient-ring selection, repair failure, and patient safety. A step towards assessing these challenges is developing a transducer that can be implanted in the exact method as commercially available rings and can quantify multidirectional ring loading. An annuloplasty ring transducer was developed to measure stresses at eight locations on both the in-plane and out-of-plane surfaces of an annuloplasty ring's titanium core. The transducer was implanted in an ovine subject using 10 sutures at near symmetric locations. At implantation, the ring was observed to undersize the mitral annulus. The flaccid annulus exerted both compressive (−) and tensile stresses (+) on the ring ranging from −3.17 to 5.34 MPa. At baseline hemodynamics, stresses cyclically changed and peaked near mid-systole. Mean changes in cyclic stress from ventricular diastole to mid-systole ranged from −0.61 to 0.46 MPa (in-plane direction) and from −0.49 to 1.13 MPa (out-of-plane direction). Results demonstrate the variability in ring stresses that can be introduced during implantation and the cyclic contraction of the mitral annulus. Ring stresses at implantation were approximately 4 magnitudes larger than the cyclic changes in stress throughout the cardiac cycle. These methods will be extended to ring transducers of differing size and geometry. Upon additional investigation, these data will contribute to improved knowledge of annulus-ring stresses, LV function, and the safer development of mitral repair techniques.
Keywords:Mitral valve   Mitral annuloplasty   Transducer   Strain gage   Mitral valve repair
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏