首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Validation of shear wave elastography in skeletal muscle
Authors:Sarah F Eby  Pengfei Song  Shigao Chen  Qingshan Chen  James F Greenleaf  Kai-Nan An
Institution:1. Mayo Medical School, Mayo Graduate School, and the Medical Scientist Training Program, College of Medicine, Mayo Clinic, Rochester, MN, United States;2. Mayo Graduate School, College of Medicine, Mayo Clinic, Rochester, MN, United States;3. Physiology and Biomedical Engineering, College of Medicine, Mayo Clinic, Rochester, MN, United States;4. Cardiovascular Diseases, College of Medicine, Mayo Clinic, Rochester, MN, United States;5. Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN, United States
Abstract:Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical properties based on the propagation of remotely induced shear waves. The objective of this study is to validate SWE throughout the functional range of motion of skeletal muscle for three ultrasound transducer orientations. We hypothesized that combining traditional materials testing (MTS) techniques with SWE measurements will show increased stiffness measures with increasing tensile load, and will correlate well with each other for trials in which the transducer is parallel to underlying muscle fibers. To evaluate this hypothesis, we monitored the deformation throughout tensile loading of four porcine brachialis whole-muscle tissue specimens, while simultaneously making SWE measurements of the same specimen. We used regression to examine the correlation between Young′s modulus from MTS and shear modulus from SWE for each of the transducer orientations. We applied a generalized linear model to account for repeated testing. Model parameters were estimated via generalized estimating equations. The regression coefficient was 0.1944, with a 95% confidence interval of (0.1463–0.2425) for parallel transducer trials. Shear waves did not propagate well for both the 45° and perpendicular transducer orientations. Both parallel SWE and MTS showed increased stiffness with increasing tensile load. This study provides the necessary first step for additional studies that can evaluate the distribution of stiffness throughout muscle.
Keywords:Ultrasonography  Passive stiffness  Materials testing  Elastic moduli  Shear wave elastography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号