首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Finite element analysis and computed tomography based structural rigidity analysis of rat tibia with simulated lytic defects
Authors:John A Rennick  Ara Nazarian  Vahid Entezari  James Kimbaris  Alan Tseng  Aidin Masoudi  Hamid Nayeb-Hashemi  Ashkan Vaziri  Brian D Snyder
Institution:1. Center for Advanced Orthopaedic Studies, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA;2. Department of Orthopaedic Surgery, Children′s Hospital, Harvard Medical School, Boston, MA, USA;3. Department of Mechanical Engineering, Northeastern University, Boston, MA, USA
Abstract:Finite element analysis (FEA), CT based structural rigidity analysis (CTRA) and mechanical testing is performed to assess the compressive failure load of rat tibia with simulated lytic defects.
Keywords:Finite element analysis  Structural rigidity analysis  Metastatic disease  Lytic defect  Rat
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏