Specific antisera suitable for solid-phase radioimmunoassay of 11beta-hydroxyandrost-4-ene-3,17-dione |
| |
Authors: | P N Rao P H Moore J W Goldzieher |
| |
Institution: | Southwest Foundation for Research and Education San Antonio, Texas 78284USA |
| |
Abstract: | Specific antiserum has been developed for use in measuring 11β-hydroxyandrost-4-ene-3, 17-dione by radioimmunoassay (RIA). Rabbit antiserum was generated by employing the conjugate prepared by coupling 6β,11β-dihydroxyandrost-4-ene-3,17-dione 6-hemisuccinate with bovine serum albumin. The antiserum bound 68% of 50 picograms of 11β-hydroxyandrost-4-ene-3,17-dione-1,2,6,7-3H] during characterization at a dilution of 1:12,500. Among the numerous steroids tested for cross-reactivity, 5α-androstane-3,17-dione, androst-4-ene-3,17-dione, and 11β-hydroxy-5α-androstane-3, 17-dione showed 2%, 5%, and 30% cross-reactivity respectively. The Rivanol-treated antiserum was coupled to Enzacryl AA, in order to study the feasibility of a solid-phase RIA, and this complex showed 50% binding with the labeled antigen at a dilution of 1:3000. The complex retained high specificity and should prove useful in a simple solid-phase RIA. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|