首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root
Authors:Jonathon Bailey  Nick Curzen
Institution:1. Computational Engineering and Design Group, Faculty of Engineering and the Environment, The University of Southampton, Building 176, Room 5017, Boldrewood Campus, Southampton, Hampshire SO16 7QF, UK;2. Southampton University Hospitals NHS Trust, E Level North Wing, Southampton SO16 6YD, UK
Abstract:Computational simulation of transcatheter aortic valve implantation (TAVI) device deployment presents a significant challenge over and above similar simulations for percutaneous coronary intervention due to the presence of prosthetic leaflets. In light of the complexity of these leaflets, simulations have been performed to assess the effect of including the leaflets in a complete model of a balloon-expandable TAVI device when deployed in a patient-specific aortic root. Using an average model discrepancy metric, the average frame positions (with and without the leaflets) are shown to vary by 0.236% of the expanded frame diameter (26 mm). This relatively small discrepancy leads to the conclusion that for a broad range of replacement valve studies, including new frame configurations and designs, patient-specific assessment of apposition, paravalvular leakage and tissue stress, modelling of the prosthetic leaflets is likely to have a marginal effect on the results
Keywords:TAVI  TAVR  leaflets  simulation  deploy and FEA
设为首页 | 免责声明 | 关于勤云 | 加入收藏