On-site audits to investigate the quality of radiation physics of radiation therapy institutions in the Republic of Korea
Affiliation:1. Division of Cardiology, Department of Internal Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea;2. Department of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, South Korea;3. Division of Cardiology, Dietrich Bonhoeffer Hospital, Academic Teaching Hospital of University of Greifswald, Greifswald, Germany;4. Department of Medicine, Keimyung University Dongsan Medical Center, Daegu, South Korea;5. Department of Medicine, Inje University Ilsan Paik Hospital, Goyang, South Korea;6. Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, South Korea;7. Institute on Aging, Seoul National University, Seoul, South Korea
Abstract:PurposeTo investigate and improve the domestic standard of radiation therapy in the Republic of Korea.MethodsOn-site audits were performed for 13 institutions in the Republic of Korea. Six items were investigated by on-site visits of each radiation therapy institution, including collimator, gantry, and couch rotation isocenter check; coincidence between light and radiation fields; photon beam flatness and symmetry; electron beam flatness and symmetry; physical wedge transmission factors; and photon beam and electron beam outputs.ResultsThe average deviations of mechanical collimator, gantry, and couch rotation isocenter were less than 1 mm. Those of radiation isocenter were also less than 1 mm. The average difference between light and radiation fields was 0.9 ± 0.6 mm for the field size of 20 cm × 20 cm. The average values of flatness and symmetry of the photon beams were 2.9% ± 0.6% and 1.1% ± 0.7%, respectively. Those of electron beams were 2.5% ± 0.7% and 0.6% ± 1.0%, respectively. Every institutions showed wedge transmission factor deviations less than 2% except one institution. The output deviations of both photon and electron beams were less than ±3% for every institution.ConclusionsThrough the on-site audit program, we could effectively detect an inappropriately operating linacs and provide some recommendations. The standard of radiation therapy in Korea is expected to improve through such on-site audits.
Keywords:On-site audits  Radiation therapy  Quality assurance  Dosimetry intercomparison  Linac
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号