首页 | 本学科首页   官方微博 | 高级检索  
     


A marker-based measurement procedure for unconstrained wrist and elbow motions.
Authors:R Schmidt  C Disselhorst-Klug  J Silny  G Rau
Affiliation:Helmholtz-Institute for Biomedical Engineering at Aachen University of Technology, Germany. rschmidt@hia.rwth-aachen.de
Abstract:A protocol is proposed to obtain the joint angles of wrist and elbow from tracked triads of surface markers on each limb segment. Cuffs placed on the limb support the rigidity of the triads. Additional markers are used to mark the approximate positions of joints. Corrections of surface marker data for skin motion are derived from a priori knowledge about plausible joint motions. In addition, ill-conditioned states are trapped when the elbow is nearly fully extended. The protocol is applied to sample motions which demonstrate the use and the effect of the corrections. The results show that the model assumptions are reasonable and that accurate joint rotations can be obtained. The correction steps prove to be an essential part of upper-extremity movement analysis.
Keywords:
本文献已被 ScienceDirect 等数据库收录!