EMG stability as a biofeedback control
Authors:Andrew Harver  Joyce Segreto  Harry Kotses
Institution:(1) University of North Carolina, Charlotte;(2) Youngstown State University, USA;(3) Psychology Department, Ohio University, 45701 Athens, Ohio
Abstract:Factors that may confound comparisons between electromyographic (EMG) biofeedback training and its control conditions include feedback quality and experience of success. We investigated the usefulness of a control procedure designed to overcome these potential sources of confounding. The procedure consisted of training muscle tension stability. We used it as a control for frontal EMG relaxation training in children with asthma. To equate the groups for feedback quality and experience of success, we gave each child in the control condition audio feedback decreasing in pitch when muscle tension was at or near baseline levels, and feedback increasing in pitch when muscle tension was either substantially above or below baseline levels. Children in both groups were instructed to decrease the pitch of the tone. In comparison to children in the relaxation condition, the children in the control condition exhibited stable levels of muscle tension throughout eight training sessions. We concluded that feedback for stable muscle tension may be a useful control procedure for EMG biofeedback training whenever experimental and control procedures differ in either feedback quality of degree to which they permit subjects to experience success.This research was supported by NIH-Grant HL 27402. We are grateful to Paul Schnitter who constructed the EMG stability feedback device.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号