首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Inactivation of Escherichia coli, Listeria monocytogenes, Pseudomonas aeruginosa and Staphylococcus aureus on stainless steel and glass surfaces by neutral electrolysed water
Authors:Deza M A  Araujo M  Garrido M J
Institution:Institute of Food Research and Analysis, University of Santiago de Compostela, Santiago de Compostela, Spain. madeza@usc.es
Abstract:AIM: To ascertain the efficacy of neutral electrolysed water (NEW) in reducing Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Listeria monocytogenes on glass and stainless steel surfaces. Its effectiveness for that purpose is compared with that of a sodium hypochlorite (NaClO) solution with similar pH, oxidation-reduction potential (ORP) and active chlorine content. METHODS AND RESULTS: First, the bactericidal activity of NEW was evaluated over pure cultures (8.5 log CFU ml-1) of the abovementioned strains: all of them were reduced by more than 7 log CFU ml-1 within 5 min of exposure either to NEW (63 mg l-1 active chlorine) or to NaClO solution (62 mg l-1 active chlorine). Then, stainless steel and glass surfaces were inoculated with the same strains and rinsed for 1 min in either NEW, NaClO solution or deionized water (control). In the first two cases, the populations of all the strains decreased by more than 6 log CFU 50 cm-2. No significant difference (P
Keywords:disinfectant              Escherichia coli            glass              Listeria monocytogenes            neutral electrolysed water              Pseudomonas aeruginosa                        Staphylococcus aureus            stainless steel  surfaces
本文献已被 PubMed 等数据库收录!