首页 | 本学科首页   官方微博 | 高级检索  
   检索      


A sensitive method for determination of 5-fluorouracil and 5-fluoro-2'-deoxyuridine in human plasma by high-pressure liquid chromatography
Authors:A R Buckpitt  M R Boyd
Institution:1. Laboratory of Molecular Biology, University of Wisconsin, Madison, Wisconsin 53706 USA;2. School of Biological Sciences, University of Kentucky, Lexington, Kentucky 40506 USA;3. Division of Biology, Kansas State University, Manhattan, Kansas 66506 USA
Abstract:Polymerization-competent extracts of suspension-cultured HeLa cells and porcine brain tissue were assayed for tubulin content. Five different methods were used to assay identically prepared extracts: two types of sodium dodecyl sulfate-containing acrylamide gels, a DEAE retention assay, a colchicine-binding assay, and a radioimmunoassay. The colchicine-binding and radioimmunoassay results were in close agreement and are therefore considered reliable assays for tubulin content in cell extracts. The DEAE retention assay gave slight overestimates, but the gel methods seriously overestimated tubulin content. Based on data from colchicine binding and radioimmunoassay, the proportion of soluble cell protein which is tubulin is 4.3% for HeLa cell extracts and 12.1% for brain tissue extracts.
Keywords:To whom correspondence should be addressed  
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏