首页 | 本学科首页   官方微博 | 高级检索  
   检索      


A new fluorescence probe for sofosbuvir analysis in dosage form and spiked human plasma
Authors:Mohamed S Nasr  Wael Talaat  Samir Morshedy  Mohamed M Y Kaddah  Gamal Omran  Reda M Keshk
Institution:1. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Damanhour University, Damanhour, Egypt

Contribution: Conceptualization, Formal analysis, ?Investigation, Methodology, Validation, Writing - original draft, Writing - review & editing;2. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Damanhour University, Damanhour, Egypt;3. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Damanhour University, Damanhour, Egypt

Contribution: Conceptualization, ?Investigation, Methodology, Supervision, Validation, Visualization, Writing - review & editing;4. Pharmaceutical and Fermentation Industries Development Center, City of Scientific Research and Technological Applications, New Borg El-Arab, Alexandria, Egypt;5. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Damanhour University, Damanhour, Egypt

Contribution: Supervision;6. Department of Chemistry, Faculty of Science, Damanhour University, Damanhour, Egypt

Abstract:A simple, rapid, and low-cost technique was developed to allow reliable analysis of the anti-hepatitis C drug sofosbuvir in bulk, tablet form, and spiked human plasma. This method depends on the ability of sofosbuvir to quench the fluorescence of the newly synthesized 2-amino-3-cyano-4,6-dimethylpyridine (reagent 3 ). Elemental analysis and spectral data were used to validate the structure of the synthesized reagent. The newly synthesized reagent exhibited a satisfactory level of fluorescence emission at 365 nm after excitation at 247 nm. All experimental variables that might affect the quenching process were analyzed and optimized. Linearity, range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) were all validated in accordance with the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines. The concentration range was shown to be linear between 0.1 and 1.5 μg/mL. The technique was effectively utilized for sofosbuvir analysis in both its tablet dosage form and spiked human plasma, with mean percentage recoveries of 100.13 ± 0.35 and 94.26 ± 1.69, respectively.
Keywords:anti-hepatitis C drug  fluorescence quenching  fluorescent probes  sofosbuvir
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号