首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Environmentally benign first derivative synchronous spectrofluorimetry for the analysis of two binary mixtures containing duloxetine with avanafil or tadalafil in spiked plasma samples
Authors:Walaa Nabil Abd-AlGhafar  Rasha Abo Shabana  Rania El-Shaheny  Manar M Tolba
Institution:1. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt;2. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt

Contribution: Conceptualization, ​Investigation, Resources, Supervision, Validation, Writing - review & editing;3. Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt

Contribution: Conceptualization, ​Investigation, Supervision, Validation, Writing - review & editing

Abstract:Antidepressants can cause sexual dysfunction side effects, necessitating the co-administration of phosphodiesterase type 5 inhibitors. The simultaneous determination of these drugs in biological fluids is critical for therapeutic drug monitoring. For the first time, two binary mixtures containing duloxetine with either avanafil or tadalafil were estimated utilizing simple green spectrofluorimetric methods without the need for a previous separation step. The study was based on first derivative synchronous spectrofluorimetry in ethanol using a change in wavelength difference (∆λ) of 20 and 25 nm for the first and second combinations, respectively. Duloxetine and avanafil were estimated at 297.7 and 331 nm in their binary mixture, while duloxetine and tadalafil were determined at 290.3 and 297.7 nm, respectively. The linearity was achieved over the ranges of 0.1–1.5 μg mL−1 for both duloxetine and avanafil and 0.01–0.40 μg mL−1 for tadalafil, with limits of detection of 0.013, 0.022, and 0.004 μg mL−1 for duloxetine, avanafil, and tadalafil, respectively. Successful application of the developed approaches was accomplished for the estimation of the two mixtures in dosage forms as well as human plasma with excellent percentage recoveries (96–103.75% in plasma), which supports their suitability for use in quality control laboratories and pharmacokinetic studies. Moreover, the adopted approaches' greenness was evidenced by applying three tools.
Keywords:avanafil  derivative synchronous spectrofluorimetry  duloxetine  human plasma  tadalafil