首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Validation of a hypoxia-inducible factor-1 alpha specimen collection procedure and quantitative enzyme-linked immunosorbent assay in solid tumor tissues
Authors:Sook Ryun Park  Robert J Kinders  Sonny Khin  Melinda Hollingshead  Smitha Antony  Ralph E Parchment  Joseph E Tomaszewski  Shivaani Kummar  James H Doroshow
Institution:1. Division of Cancer Treatment and Diagnosis, National Cancer Institute, Bethesda, MD 20892, USA;2. Laboratory of Human Toxicology and Pharmacology, Applied/Developmental Research Directorate, Leidos Biomedical Research, Frederick National Laboratory for Cancer Research, Frederick, MD 21702, USA;3. Biological Testing Branch, Developmental Therapeutics Program, Frederick National Laboratory for Cancer Research, Frederick, MD 20892, USA;4. Center for Cancer Research, National Cancer Institute, Bethesda, MD 20892, USA
Abstract:Hypoxia-inducible factor-1 alpha (HIF-1α) is an important marker of hypoxia in human tumors and has been implicated in tumor progression. Drugs targeting HIF-1α are being developed, but the ability to measure drug-induced changes in HIF-1α is limited by the lability of the protein in normoxia. Our goal was to devise methods for specimen collection and processing that preserve HIF-1α in solid tumor tissues and to develop and validate a two-site chemiluminescent quantitative enzyme-linked immunosorbent assay (ELISA) for HIF-1α. We tested various strategies for HIF-1α stabilization in solid tumors, including nitrogen gas-purged lysis buffer, the addition of proteasome inhibitors or the prolyl hydroxylase inhibitor 2-hydroxyglutarate, and bead homogenization. Degassing and the addition of 2-hydroxyglutarate to the collection buffer significantly increased HIF-1α recovery, whereas bead homogenization in sealed tubes improved HIF-1α recovery and reduced sample variability. Validation of the ELISA demonstrated intra- and inter-assay variability of less than 15% and accuracy of 99.8 ± 8.3% as assessed by spike recovery. Inter-laboratory reproducibility was also demonstrated (R2 = 0.999). Careful sample handling techniques allow us to quantitatively detect HIF-1α in samples as small as 2.5 μg of total protein extract, and this method is currently being applied to analyze tumor biopsy specimens in early-phase clinical trials.
Keywords:Hypoxia-inducible factor  HIF-1α  Quantitative ELISA  Pharmacodynamics  Solid tumors
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号