首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Quantification of regional right ventricular strain in healthy rats using 3D spiral cine dense MRI
Institution:1. Institute of Computer Science, Foundation of Research and Technology, Hellas, Heraklion, Crete, Greece;2. Applied Photonics Group,Faculty of Engineering, University of the Basque Country, Bizkaia, Spain;3. Department of Computer Science, University of Crete, Heraklion, Crete, Greece;2. National Heart Centre, Singapore, 5 Hospital Drive, Singapore 169609, Singapore;3. Department of Clinical Physiology, Karolinska University Hospital, and Karolinska Institutet, Stockholm, Sweden.;1. Department of Biomedical Engineering, University of Kentucky, Lexington, KY, United States;2. Department of Imaging Science and Innovation, Geisinger, Danville, PA, United States;3. Department of Medical & Health Physics, Geisinger, Danville, PA, United States;4. Department of Electrical Engineering, University of Kentucky, Lexington, KY, United States;5. Department of Physiology, University of Kentucky, Lexington, KY, United States;6. MR R&D Collaborations, Siemens Healthcare, Atlanta, GA, United States;7. Department of Radiology, Geisinger, Danville, PA, United States
Abstract:Statistical data from clinical studies suggests that right ventricular (RV) circumferential strain (Ecc) and longitudinal strain (Ell) are significant biomarkers for many cardiovascular diseases. However, a detailed and regional characterization of these strains in the RV is very limited. In the current study, RV images were obtained with 3D spiral cine DENSE MRI in healthy rats. An algorithm for surface growing was proposed in order to fit irregular topology. Specifically, a new custom plugin for the DENSEanalysis program, called 3D DENSE Plugin for Crescent Organ, was developed for surface reconstruction and precise segmentation of organs with sharp curvature, such as the murine RV. The RV free wall (RVFW) was divided into three longitudinal thirds (i.e., basal, middle, and apical) with each one partitioned into circumferential fourths (i.e., anterior, anteriorlateral, inferiorlateral and inferior). Peak systolic strains were quantified for each segment and comparisons were performed statistically. The inclusion of a new plugin was able to generate global values for Ecc and Ell that are in good agreement with previous findings using MRI. Despite no regional variation found in the peak Ecc, the peak Ell exhibited regional variation at the anterior side of the RV, which is potentially due to differences in biventricular torsion at the RV insertion point and fiber architecture. These results provide fundamental insights into the regional contractile function of the RV in healthy rat and could act as a normative baseline for future studies on regional changes induced by disease or treatment.
Keywords:3D DENSE plugin for Crescent Organ  3D lagrangian strain  Surface fitting
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号