PIXE technique for calcium analysis of human bone |
| |
Authors: | E. Caruso G. M. Braga Marcazzan P. Redaelli E. Bonucci P. Ballanti S. Mazzaferro G. Coen |
| |
Affiliation: | 1. CISE Spa, PO Box 12081, 20134, Milan, Italy 2. Istituto di Fisica Generale Applicata dell'Università, Milan, Italy 3. Department of Human Biopathology and 2nd Clinica Medica, University ?La Sapienza?, Rome, Italy
|
| |
Abstract: | The determination of calcium content in human bone tissue is very useful in metabolic diseases of bone, such as renal osteodystrophy, osteoporosis, hyperparathyroidism, and osteomalacia of diverse etiology. The PIXE technique allows calcium to be directly determined in bioptic tissue sections properly, sampled for histological optical and/or electron microscopy examination. Bone semithin sections (3 μm thick, 4×4 mm2 dimensions), cut by ultramicrotome and deposited onto polyvinyl acetate films, underwent PIXE analysis using the CISE set-up. Histomorphometric (after standard staining), evaluation of calcified bone volume (CBV) in absolute value allows calcium density to be determined. A total of nine bone biopsies were analyzed (three sections each) obtaining values ranging between 352 and 482, with an average value of 421.5±15.3 (M±SE) μg/μL, in good agreement with literature data (obtained by AAS technique on dissected bone samples). The aim of this paper is to emphasize the usefulness, of combined PIXE and histomorphometric techniques for the study of calcium content in bone tissue in both healthy and diseased bones. |
| |
Keywords: | PIXE calcium content, of bone bone histomorphometry nuclear analytical methods |