Increased yield of high purity recombinant human interferon-gamma utilizing reversed phase column chromatography |
| |
Authors: | Reddy Praveen K Reddy Srinivasa G Narala Venkata R Majee Sangita S Konda Sudhakar Gunwar Sripad Reddy Raju C |
| |
Affiliation: | Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, MI 48109, USA. |
| |
Abstract: | Increasing therapeutic applications for recombinant human interferon-gamma (rhIFN-gamma), an antiviral proinflammatory cytokine, has broadened interest in optimizing methods for its production and purification. We describe a reversed phase chromatography (RPC) procedure using Source-30 matrix in the purification of rhIFN-gamma from Escherichia coli that results in a higher yield than previously reported. The purified rhIFN-gamma monomer from the RPC column is refolded in Tris buffer. Optimal refolding occurs at protein concentrations between 50 and 100 microg/ml. This method yields greater than 90% of the dimer form with a yield of 40 mg/g cell mass. Greater than 99% purity is achieved with further purification over a Superdex G-75 column to obtain specific activities of from 2 x 10(7) to 4 x 10(7)IU/mg protein as determined via cytopathic antiviral assay. The improved yield of rhIFN-gamma in a simple chromatographic purification procedure promises to enhance the development and therapeutic application of this biologically potent molecule. |
| |