首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Treatment planning systems dosimetry auditing project in Portugal
Institution:1. Department of Neurology, Louisiana State University Health Sciences Center, New Orleans, LA, United States;2. Department of Internal Medicine, Section of Physical Medicine and Rehabilitation, United States;3. Department of Anesthesiology, Louisiana State University Health Sciences Center, New Orleans, LA, United States;4. Department of Neuroscience Center of Excellence, Louisiana State University Health Sciences Center, New Orleans, LA, United States;5. Center of Excellence for Oral and Craniofacial Biology, Louisiana State University Health Sciences Center, New Orleans, LA, United States;6. Pain Mastery Center of Louisiana, Louisiana State University Health Sciences Center, New Orleans, LA, United States
Abstract:Background and purposeThe Medical Physics Division of the Portuguese Physics Society (DFM_SPF) in collaboration with the IAEA, carried out a national auditing project in radiotherapy, between September 2011 and April 2012. The objective of this audit was to ensure the optimal usage of treatment planning systems. The national results are presented in this paper.Material and methodsThe audit methodology simulated all steps of external beam radiotherapy workflow, from image acquisition to treatment planning and dose delivery. A thorax CIRS phantom lend by IAEA was used in 8 planning test-cases for photon beams corresponding to 15 measuring points (33 point dose results, including individual fields in multi-field test cases and 5 sum results) in different phantom materials covering a set of typical clinical delivery techniques in 3D Conformal Radiotherapy.ResultsAll 24 radiotherapy centers in Portugal have participated. 50 photon beams with energies 4–18 MV have been audited using 25 linear accelerators and 32 calculation algorithms.In general a very good consistency was observed for the same type of algorithm in all centres and for each beam quality.ConclusionsThe overall results confirmed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy is generally acceptable with no major causes for concern. This project contributed to the strengthening of the cooperation between the centres and professionals, paving the way to further national collaborations.
Keywords:Treatment planning systems  Dosimetry audit  Dose calculation algorithms
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号