首页 | 本学科首页   官方微博 | 高级检索  
   检索      


The biomechanical properties of canine skin measured in situ by uniaxial extension
Authors:Camille Bismuth  Clothilde Gerin  Eric Viguier  Didier Fau  Florence Dupasquier  Laurent Cavetier  Laurent David  Claude Carozzo
Institution:1. CHEVAC, Small Animal Department, VetAgro Sup, Campus vétérinaire de Lyon, University of Lyon, F-69280 Marcy l''Etoile, France. UPSP 2011.03.101 ICE, VetAgro Sup, Université de Lyon, 69280 Marcy L''Etoile, France;2. Université de Lyon, Université Claude Bernard Lyon 1, Laboratoire Ingénierie des Matériaux Polymères (IMP@Lyon1), CNRS UMR 5223, Bât. Polytech Lyon, 15 bd Latarjet 69622, Villeurbanne Cedex, France
Abstract:

Introduction

A uniaxial extension system was setup to analyze the mechanical properties of dog skin.

Material and methods

Pads were glued onto dog skin with constant reproducible geometrical parameters and the extension force was measured as a function of the extension values. Forty-one sites (82 cycling tests) were investigated in situ on 11 canine cadavers, half of them after surgically isolating the test area from the surrounding skin. Series of loading-unloading cycles of up to 5 N or 10 N or both loads were performed on each site. The elastic properties and the dissipative effects were characterized respectively by evaluating the secant Rigidity at maximum loads and the Fraction of dissipated energy.

Results

A hysteresis phenomenon, implying the need for preconditioning to attain equilibrium cycles, was apparent during mechanical characterization. Polynomial expressions were used to relate the measured Rigidities and the Fractions of dissipated energy with or without sample isolation. The latter were less affected by isolation. The ratios between the Rigidities at 5 N to those at 10 N displayed non-linearity in the investigated extension range in contrary to the Fractions of dissipated energy.

Discussion/conclusion

The parameters confirming the dissipative non-linear elastic behavior of dog skin were identified and the correlation between Rigidity and Fraction of dissipated energy on isolated and non-isolated skin samples was quantitatively determined. This extension setup can now be used as a “true in vivo” mapping tool to determine the mechanical characteristics of the skin during healing processes or during the study of Human skin disease with the dog as an animal model.
Keywords:Skin measurement device  Extensometer  Biomechanical properties  In vivo  Dogs
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号