Comparison of mitral annulus geometry between patients with ischemic and non-ischemic functional mitral regurgitation: implications for transcatheter mitral valve implantation
Authors:Patrizia Aruta  Denisa Muraru  Andrada Camelia Guta  Sorina Mihaila  Niccolò Ruozi  Chiara Palermo  Basma Elnagar  Sabino Iliceto  Luigi P. Badano
Affiliation:1.Department of Cardiac, Thoracic and Vascular Science,University of Padua,Padua,Italy;2.University of Medicine and Pharmacy “Carol Davila”,Bucharest,Romania;3.Tanta University Hospital,Tanta,Egypt
Abstract:

Background

Transcatheter mitral valve replacement (TMVR) is a new therapeutic option for high surgical risk patients with mitral regurgitation (MR). Mitral valve (MV) geometry quantification is of paramount importance for success of the procedure and transthoracic 3D echocardiography represents a useful screening tool. Accordingly, we sought to asses MV geometry in patients with functional MR (FMR) that would potentially benefit of TMVR, focusing on the comparison of mitral annulus (MA) geometry between patients with ischemic (IMR) and non ischemic mitral regurgitation (nIMR).

Methods

We retrospectively selected 94 patients with severe FMR: 41 (43,6%) with IMR and 53 (56,4%) with nIMR. 3D MA analysis was performed on dedicated transthoracic 3D data sets using a new, commercially-available software package in two moments of the cardiac cycle (early-diastole and mid-systole). We measured MA dimension and geometry parameters, left atrial and left ventricular volumes.

Results

Maximum (MA area 10.7?±?2.5 cm2 vs 11.6?±?2.7 cm2, p?>?0.05) and the best fit plane MA area (9.9?±?2.3 cm2 vs 10.7?±?2.5 cm2, p?>?0.05, respectively) were similar between IMR and nIMR. nIMR patients showed larger mid-systolic 3D area (9.8?±?2.3 cm2 vs 10.8?±?2.7 cm2, p?p?p?2 vs 9.9?±?1.5 cm2, p?>?0.05).

Conclusions

Patients with ischemic and non-ischemic etiology of FMR have similar maximum dimension, yet systolic differences between the two groups should be taken into account to tailor prosthesis’s selection.

Trial registration

N.A.
Keywords: