首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Standard Automated Perimetry versus Matrix Frequency Doubling Technology Perimetry in Subjects with Ocular Hypertension and Healthy Control Subjects
Authors:Julia Lamparter  Shakhsanam Aliyeva  Andreas Schulze  Manfred Berres  Norbert Pfeiffer  Esther M Hoffmann
Institution:1. Department of Ophthalmology, University Medical Centre Mainz, Mainz, Germany.; 2. Institute of Medical Biometry, Epidemiology and Informatics, University Medical Centre Mainz, Mainz, Germany.; 3. University of Applied Sciences Koblenz, RheinAhrCampus Remagen, Remagen, Germany.; Eye Hospital, Charité, Germany,
Abstract:

Background

To evaluate the relationship and agreement between standard automated perimetry (SAP) and Matrix frequency doubling technology (Matrix-FDT) in subjects with ocular hypertension and healthy control subjects.

Methods

Forty-four eyes of 44 ocular hypertensive subjects and 29 eyes of 29 healthy age-matched control subjects were included in this prospective study. All participants underwent complete ophthalmic examination, including slit-lamp biomicroscopy, intraocular pressure measurement, pachymetry, and dilated fundus examination, and showed reliable visual field tests. One randomly selected eye of each participant was examined with SAP (Swedish Interactive Threshold Algorithm SITA] Standard 24-2 test) and Matrix-FDT (24-2 threshold test), in random order. Correlations between global indices (MD, PSD), regions (2 hemifields, 4 quadrants, 6 sectors) and 52 single field positions were analyzed using Spearman’s rank correlation coefficient.

Results

In both groups, mean deviation values of SAP and Matrix-FDT correlated significantly (OHT subjects: r = 0.47, p<0.005; healthy subjects: r = 0.68; p<0.001, respectively). Pattern standard deviation of SAP and Matrix-FDT showed no significant correlation in healthy subjects but correlated significantly in ocular hypertensive subjects (r = 0.45, p<0.005). In healthy subjects, a significant correlation between SAP and Matrix-FDT was shown in the supero-temporal and infero-temporal sectors of the disc (r = 0.40 and r = 0.38, p<0.05, respectively). In OHT subjects, supero-temporal, supero-nasal and nasal sectors correlated significantly (r = 0.49, 0.62 and 0.38, p≤0.01, respectively). The correlation pattern of individual visual field test locations appeared heterogeneous in both groups.

Conclusions

In both, ocular hypertensive and healthy subjects SAP and Matrix-FDT correlate well. In ocular hypertensive subjects, both techniques showed good correlation in the supero-temporal, supero-nasal, and nasal sectors of the disc. Poor agreement was found in the temporal, infero-temporal and infero-nasal disc sectors. This missing correlation might be related to early retinal nerve fiber layer damage in these regions of the disc, recognized by one of the visual field instruments.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号