首页 | 本学科首页   官方微博 | 高级检索  
     


Left Atrial Appendage Closure Guided by Integrated Echocardiography and Fluoroscopy Imaging Reduces Radiation Exposure
Authors:Christiane Jungen  Tobias Zeus  Jan Balzer  Eickholt Christian  Margot Petersen  Eva Kehmeier  Verena Veulemans  Malte Kelm  Stephan Willems  Christian Meyer
Affiliation:1 Department of Cardiology—Electrophysiology, cNEP, cardiac Neuro- and Electrophysiology research group, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany, DZHK (German Center for Cardiovascular Research), partner site Hamburg/Kiel/Luebeck, Hamburg, Germany, ; 2 Department of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Hospital Duesseldorf, Duesseldorf, Germany, ; University of Messina, ITALY,
Abstract:

Aims

To investigate whether percutaneous left atrial appendage (LAA) closure guided by automated real-time integration of 2D-/3D-transesophageal echocardiography (TEE) and fluoroscopy imaging results in decreased radiation exposure.

Methods and Results

In this open-label single-center study LAA closure (AmplatzerTM Cardiac Plug) was performed in 34 consecutive patients (8 women; 73.1±8.5 years) with (n = 17, EN+) or without (n = 17, EN-) integrated echocardiography/fluoroscopy imaging guidance (EchoNavigator® [EN]; Philips Healthcare). There were no significant differences in baseline characteristics between both groups. Successful LAA closure was documented in all patients. Radiation dose was reduced in the EN+ group about 52% (EN+: 48.5±30.7 vs. EN-: 93.9±64.4 Gy/cm2; p = 0.01). Corresponding to the radiation dose fluoroscopy time was reduced (EN+: 16.7±7 vs. EN-: 24.0±11.4 min; p = 0.035). These advantages were not at the cost of increased procedure time (89.6±28.8 vs. 90.1±30.2 min; p = 0.96) or periprocedural complications. Contrast media amount was comparable between both groups (172.3±92.7 vs. 197.5±127.8 ml; p = 0.53). During short-term follow-up of at least 3 months (mean: 8.1±5.9 months) no device-related events occurred.

Conclusions

Automated real-time integration of echocardiography and fluoroscopy can be incorporated into procedural work-flow of percutaneous left atrial appendage closure without prolonging procedure time. This approach results in a relevant reduction of radiation exposure.

Trial Registration

ClinicalTrials.gov NCT01262508