首页 | 本学科首页   官方微博 | 高级检索  
   检索      


The influence of storage temperature during machine perfusion on preservation quality of marginal donor livers
Authors:Peter Olschewski  Paul Gaß  Veeravorn Ariyakhagorn  Kerstin Jasse  Gerhard Hunold  Martin Menzel  Wenzel Schöning  Volker Schmitz  Peter Neuhaus  Gero Puhl
Institution:aClinic for General, Visceral and Transplantation Surgery, Charité Campus Virchow-Klinikum, University Medicine Berlin, Germany;bDepartment of Surgery, Chiangmai University, Chiangmai, Thailand
Abstract:

Background

Although non-heart-beating donors have the potential to increase the number of available organs, the livers are used very seldom because of the risk of primary non-function. There is evidence that machine perfusion is able to improve the preservation of marginal organs, and therefore we evaluated in our study the influence of the perfusate temperature during oxygenated machine perfusion on the graft quality.

Methods

Livers from male Wistar rats were harvested after 60-min warm ischemia induced by cardiac arrest. The portal vein was cannulated and the liver flushed with Lifor® (Lifeblood Medical, Inc.) organ preservation solution for oxygenated machine perfusion (MP) at 4, 12 or 21 °C. Other livers were flushed with HTK and stored at 4 °C by conventional cold storage (4 °C-CS). Furthermore two groups with either warm ischemic damage only or without any ischemic damage serve as control groups. After 6 h of either machine perfusion or cold storage all livers were normothermic reperfused with Krebs–Henseleit buffer, and functional as well as structural data were analyzed.

Results

Contrary to livers stored by static cold storage, machine perfused livers showed independently of the perfusate temperature a significantly decreased enzyme release of hepatic transaminases (ALT) during isolated reperfusion. Increasing the machine perfusion temperature to 21 °C resulted in a marked reduction of portal venous resistance and an increased bile production.

Conclusions

Oxygenated machine perfusion improves viability of livers after prolonged warm ischemic damage. Elevated perfusion temperature of 21 °C reconstitutes the hepatic functional capacity better than perfusion at 4 or 12 °C.
Keywords:Liver transplantation  Temperature  Preservation  Marginal organs  NHBD
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏