Modelling the mechanical response of elastin for arterial tissue |
| |
Authors: | Paul N. Watton Yiannis Ventikos Gerhard A. Holzapfel |
| |
Affiliation: | 1. Department of Engineering Science and Institute of Biomedical Engineering, University of Oxford, Parks Road, OX1 3PJ Oxford, UK;2. Institute of Biomechanics, Center of Biomedical Engineering, Graz University of Technology, Kronesgasse 5-I, 8010 Graz, Austria;3. Department of Solid Mechanics, School of Engineering Sciences, Royal Institute of Technology (KTH), Osquars Backe 1, 100 44 Stockholm, Sweden;1. Laboratory of Biomechanics, Center of Clinical, Experimental Surgery, and Translational Research, Biomedical Research Foundation of the Academy of Athens, Athens, Greece;2. Laboratory of Biofluid Mechanics and Biomedical Engineering, School of Mechanical Engineering, National Technical University, Athens, Greece;1. Institute of Biomechanics, Center of Biomedical Engineering, Graz University of Technology, Graz, Austria;2. Institute of Pathology, Medical University Graz, Graz, Austria;3. Department of Solid Mechanics, School of Engineering Sciences, Royal Institute of Technology (KTH), Stockholm, Sweden;1. Duke Clinical Research Institute, Duke University Medical Center, Durham, NC;2. Syntactx, New York, NY;1. Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, SAINBIOSE, F-42023 Saint Etienne, France;2. INSERM, U1059, F-42000 Saint Etienne, France;3. Université de Lyon, SAINBIOSE, F-42000 Saint Etienne, France;4. University Hospital of Saint-Etienne, Department of Cardiovascular Surgery, F-42055 Saint-Etienne cedex 2, France;1. Graz University of Technology, Institute of Biomechanics, Kronesgasse 5-I, 8010 Graz, Austria;2. Centre for Applied Biomedical Engineering Research, Department of Mechanical, Aeronautical and Biomedical Engineering and the Materials and Surface Science Institute, University of Limerick, Ireland |
| |
Abstract: | We compare two constitutive models proposed to model the elastinous constituents of an artery. Holzapfel and Weizsäcker [1998. Biomechanical behavior of the arterial wall and its numerical characterization. Comput. Biol. Med. 28, 377–392] attribute a neo-Hookean response, i.e. , to the elastin whilst Zulliger et al. [2004a. A strain energy function for arteries accounting for wall composition and structure. J. Biomech. 37, 989–1000] propose . We analyse these constitutive models for two specific cases: (i) uniaxial extension of an elastinous sheet; (ii) inflation of a cylindrical elastinous membrane. For case (i) we illustrate the functional relationships between: (a) the Cauchy stress (CS) and the Green–Lagrange (GL) strain; (b) the tangent modulus (gradient of the CS–GL strain curve) and linearised strain. The predicted mechanical responses are compared with recent uniaxial extension tests on elastin [Gundiah, N., Ratcliffe, M.B., Pruitt, L.A., 2007. Determination of strain energy function for arterial elastin: experiments using histology and mechanical tests. J. Biomech. 40, 586–594; Lillie, M.A., Gosline, J.M., 2007a. Limits to the durability of arterial elastic tissue. Biomaterials 28, 2021–2031; 2007b. Mechanical properties of elastin along the thoracic aorta in the pig. J. Biomech. 40, 2214–2221]. The neo-Hookean model accurately predicts the mechanical response of a single elastin fibre. However, it is unable to accurately capture the mechanical response of arterial elastin, e.g. the initial toe region of arterial elastin (if it exists) or the gradual increase in modulus of arterial elastin that occurs as it is stretched. The alternative constitutive model () yields a nonlinear mechanical response that departs from recent uniaxial test data mentioned above, for the same stretch range. For case (ii) we illustrate the pressure–circumferential stretch relationships and the gradients of the pressure–circumferential stretch curves: significant qualitative differences are observed. For the neo-Hookean model, the gradient decreases rapidly to zero, however, for , the gradient decreases more gradually to a constant value. We conclude that whilst the neo-Hookean model has limitations, it appears to capture more accurately the mechanical response of elastin. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|