Clinical blood chemistry values in normal Wistar-Imamichi rats using the RaBA-System (author's transl)]
Authors:T Hirano  Y Takagaki
Abstract:In order to establish the normal baseline of blood values in rats using the RaBA-System, the following eight parameters were analyzed in 8-22-week-old Wistar-Imamichi rats of both sexes: hemoglobin, total protein, glucose, BUN, total cholesterol, GOT, GPT, and alkaline phosphatase. With the exception of glucose, all these parameters were significantly different depending upon ages. Significant sex differences were observed in the values of hemoglobin, total cholesterol, GOT, and alkaline phosphatase.