首页 | 本学科首页   官方微博 | 高级检索  
     


Sensitive method for the determination of ibutilide in human plasma by liquid chromatography-tandem mass spectrometry
Authors:Tian Lei  Li Yishi  Huang Yiling  Kuang Fuhua  Li Feiou  Hua Lu
Affiliation:Clinical Pharmacology Center, Fu Wai Hospital, CAMS and PUMC, 167 Beilishi Road, Beijing 100037, PR China. ittl@fuwaihospital.org
Abstract:A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed and validated for determination of ibutilide in human plasma. The analyte and internal standard sotalol were extracted from plasma samples by liquid-liquid extraction, and separated on a C(18) column, using acetonitrile-water-10% butylamine-10% acetic acid (80:20:0.07:0.06, v/v/v/v) as the mobile phase. Detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via TurboIonSpray ionization (ESI). Linear calibration curves were obtained in the concentration range of 20-10,000 pg/ml, with a lower limit of quantitation of 10 pg/ml. The intra- and inter-day precision values were below 8% and accuracy was within +/-3% at all three QC levels. The method was utilized to support clinical pharmacokinetic studies of ibutilide in healthy volunteers following intravenous administration.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号