A comparative study of the cytoskeleton binding drugs nocodazole and taxol with a mammalian cell quartz crystal microbalance biosensor: different dynamic responses and energy dissipation effects |
| |
Authors: | Marx Kenneth A Zhou Tiean Montrone Anne McIntosh Donna Braunhut Susan J |
| |
Affiliation: | Center for Intelligent Biomaterials, Department of Chemistry, University of Massachusetts, Lowell, MA 01854, USA. Kenneth_Marx@uml.edu |
| |
Abstract: | The quartz crystal microbalance (QCM) was used to create piezoelectric whole-cell biosensors utilizing either living endothelial cells (ECs) or the metastatic human mammary cancer cell line MDA-MB-231 adhering to the gold QCM surface under in vitro growth conditions. We utilized the whole-cell QCM biosensors for the detection of the effects of varying concentrations of the microtubule binding drugs taxol and nocodazole by measuring changes in the QCM steady state frequency (Deltaf) and motional resistance (DeltaR), shift values. Using 0.11-50 microM nocodazole, we observed the Deltaf shift values of the biosensors, consisting of 20,000 ECs, to decrease significantly in magnitude (nearly 100%) to a limiting value, in a dose-dependent fashion, over a 5- to 6-h incubation period following drug addition. This effect is consistent with nocodazole's known disruption of intracellular microtubules. On the other hand, 10 microM taxol caused little alteration in Deltaf over the same time period, consistent with its microtubule hyperstabilization effect. When the EC QCM biosensor Deltaf shift values were normalized by the number of ECs found firmly attached to the QCM surface via trypsin removal and electronic counting, the dose curve was shifted to lower nocodazole concentrations, resulting in a more sensitive drug biosensor. The kinetics of the Deltaf decrease with increasing nocodazole concentrations measured by the EC QCM biosensor was found to be similar at all drug concentrations and was well fit by a single first-order exponential decay equation. For all nocodazole doses, t(0.5) was invariant, averaging t(0.5)=0.83+/-0.14 h. These data demonstrate that a single dynamic sensing system within the cell, the microtubules, is disrupted by the addition of nocodazole and this process is sensed by the cell QCM biosensor. This interpretation of the data was confirmed by a fluorescence light microscopy investigation of ECs undergoing treatment with increasing nocodazole doses using a fluorescent antibody to alpha-tubulin. These studies revealed a corresponding loss of the spread morphology of the cells, concomitant with a rearrangement of the extended native microtubules into increasingly large aggregates with the cells eventually lifting from the surface in significant numbers at 50 microM. At 6 microM nocodazole, partial reversibility of the EC QCM biosensor was demonstrated. These results indicate that the EC QCM biosensor can be used to detect and study EC cytoskeleton alterations and dynamics. We suggest the potential of this cellular biosensor for the real-time identification or screening of all classes of biologically active drugs or biological macromolecules that affect cellular attachment and cellular spreading, regardless of their molecular mechanism of action. |
| |
Keywords: | Quartz crystal microbalance Endothelial cells Biosensor Microtubules Cytoskeleton Nocodazole Taxol Dynamics Energy dissipation |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|