Fluoranthene determination based on a rapid and sensitive syringe extraction and solid-phase fluorescence technique |
| |
Authors: | Jiayan Shen Long Li Kehan Xu Kaijun Wang Yiping Du Ting Wu Huipeng Deng |
| |
Institution: | 1. College of Chemical and Molecular Engineering, East China University of Science and Technology, Shanghai, China;2. Institute of Chemistry, Henan Academy of Sciences, Zhengzhou, China;3. School of Materials Science and Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China |
| |
Abstract: | A rapid and sensitive strategy was proposed for the detection of fluoranthene (FL), which is a polycyclic aromatic hydrocarbon (PAH), in water samples. In this work, syringe solid-phase extraction (SPE) combined with solid-phase fluorescence spectrometry was used to determine FL in PAHs polluted environmental samples. The fluorescence signals were directly monitored on the membrane surface after FL was enriched by syringe SPE. Under the optimal conditions, the proposed method showed a linear relationship in the concentration range 2–50 μg/L with a correlation coefficient (R2) of 0.998, and the limit of detection was 0.143 μg/L. The recoveries varied from 93.47% to 109.81% in the actual samples, with the relative standard deviations (n = 3) ranging from 2.06% to 6.32%. According to the results, the established method can be applied in the field of rapid detection as it is fast, simple, portable, and highly sensitive, and has strong anti-interference. |
| |
Keywords: | FL rapid detection solid-phase fluorescence spectrum syringe |
|
|