首页 | 本学科首页   官方微博 | 高级检索  
     


Microfluorimetric quantification of catecholamine fluorescence in rat sympathetic ganglia
Authors:H Alho  M Partanen  A Hervonen
Affiliation:(1) Department of Biomedical Sciences, University of Tampere, Box 607, SF-33101 Tampere 10, Finland
Abstract:Summary The formaldehyde-induced fluorescence (FIF) technique was used to generate catecholamine fluorphores in the perikarya of the sympathetic neurons in the superior cervical ganglion of adult rats. During microfluorimetric quantification, the photodecomposition was eliminated by a rapid measuring procedure with a small excitation field and by using only visible light between the measurements.The catecholamine fluorescence, induced in protein microdroplets with increasing noradrenaline concentrations, was linear up to 2×10–2 M which exceeds the noradrenaline content of even the most intensively fluorescent neurons. Thus, the differences in fluorescence intensities directly reflect the physiological state of each neuron with respect to their catecholamine content. The mean histograms reveal the changes which can only occur in certain neurons, and which can disappear if the mean only is assessed. The microfluorimetric method was sensitive enough to detect even minute changes induced by reserpine treatment in the catecholamine content of the sympathetic ganglion cells.
Keywords:
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号